Customization: | Available |
---|---|
Task: | Program |
Structure: | Combination |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
CPU Features | |
Local I/O | 14 Channels DC24V DI, 10 Channels Relay DO |
Expandable I/O | 4 modules |
High-speed counter | Monophase counter: 3 points, 100KHz |
Biphase counter: 2 points, 100KHz | |
Pulse output | N/A |
Pulse catch | 3 points |
Interrupt input | 3 points |
Analog potentiometer | 2, value setting range 0 ~ 255 |
User program memory | 28K bytes/120K bytes |
capacity | |
Retain area | 512 bytes/6K bytes |
Input data memory | 512 bytes |
Output data memory | 512 bytes |
Mid-variables memory | 8K bytes |
Global memory | 24K bytes |
Password | Yes |
Real-time clock | Built-in |
Timer | No limit (1ms as minimum unit) |
Counter | No limit (Maximum counting range: 16 bit) |
Basic instructions | 283 |
Function blocks | Over 70 |
Operation speed | 0.65 μ s (Basic instruction) |
Power Supply Specifications | |
Power supply | 220V AC@50Hz |
Allowed range | 187V AC ~ 242V AC@50Hz |
Current consumption (MAX) | 120mA |
Output voltage | 24V DC |
Allowed range | 22.8V DC ~ 25.2V DC |
Current output +24VDC (To expansion bus) | 260mA |
Current output +24VDC (To expansion bus) | 2 00mA |
Current output+5V DC (To expansion bus) | 800mA |
Short circuit protection | 400mA, 24VDC output |
Communication Features | |
Communication interface | 1 RS-232 (Non-isolating) |
Communication protocol | Proprietary protocol/MODBUS/Free protocol |
Input Features | |
Input type | Sink/Source |
Input voltage rated value | 24V DC |
Allowed range | 0V DC ~ 30V DC |
Logic 1 signal | 15 ~ 30V DC, allowed minimum current 3mA |
Logic 0 signal | 0 ~ 5V DC, allowed maximum current 1mA |
Input delay time | <0.6ms (Rated input voltage) |
Isolation mode | Photocoupler isolation |
Isolation group | 2 groups |
Maximum Isolation Voltage | 1500VAC |
Output Features | |
Output type | Relay |
Output voltage | 24V DC or 24 V AC ~ 230V AC |
Allowed range | 5V DC ~ 30V DC or 5V AC ~ 250V AC |
Common end output current total | <10A |
Output switch capacity | 2A, resistance load |
Minimum load | 10mA (contact voltage 5VAC or 5VDC) |
Over current protection | N/A |
Contact impedance | <0.2 Ω |
Isolation group | 2 groups |
Isolation voltage between coil and | 3000VAC, 1 minute, leakage current 1mA |
contact | |
Isolation voltage between contacts | 750VAC, 1 minute, leakage current 1mA |
Isolation resistance (minimum) | 100M Ω between contacts or between coil |
and contact (500VDC) | |
Contact switch delay time | <10ms |
Contact switch frequency | 1Hz |
(maximum) | |
Relay mechanical life | No load: over 10,000,000 times; Rated |
Resistive load 2A: over 100,000 times | |
Physical Features | |
Dimensions | 125mm(L) × 90mm(W) × 70mm (H) |
Weight | <400g |