Nr12 Digital Power Factor Meter

Product Details
Customization: Available
Task: Program
Structure: Combination
Still deciding? Get samples of US$ 136.77/Piece
Request Sample
Diamond Member Since 2012

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
31
Year of Establishment
2005-12-13
  • Nr12 Digital Power Factor Meter
  • Nr12 Digital Power Factor Meter
  • Nr12 Digital Power Factor Meter
  • Nr12 Digital Power Factor Meter
  • Nr12 Digital Power Factor Meter
Find Similar Products

Basic Info.

Model NO.
NR12
Mathematical Model
Linear
Signal
Continuous
Function
Monitoring
Certification
CE
Condition
New
Customized
Customized
Material
Aluminum Alloy
Model
Nr12
Transport Package
Carton
Specification
ce rohs
Trademark
cnruihua
Origin
Zhejiang
Production Capacity
50000 PCS/Year

Product Description

 
Main
Range of product Var logic N
Device short name NR12
Language   English, French, German, Portuguese, Spanish
Complementary
Number of step output contacts  12
[Us] rated supply voltage  110 V AC 50/60 Hz
220-240 V AC 50/60 Hz
380-415 V AC 50/60 Hz
Measurement current  0-5 A
Measurement voltage 110 V AC 50/60 Hz
220...240 V AC 50/60 Hz
380...415 V AC 50/60 Hz
Operating mode Manual
Color code (RAL 7016)
Display type  Back-lighted screen 65 x 21 mm
Type of measurement Ambient temperature inside the cubicle
Connected steps
Cos f
History of alarms
Network technical data : load and reactive currents, voltage, powers (S, P, Q)
Switching cycles and connected time counter
Total voltage harmonic distortion THD (U)
Type of alarms Hunting (unstable regulation) / Action: message and alarm contact
Low power factor / Action: message and alarm contact
Overcompensation / Action: message and alarm contact
Total harmonic distortion (> 7 %) / Action: message and alarm contact
Low current (< 2.5 %) / Action: message
High current (> 115 %) / Action: message
Over current (> 115 % I1) / Action: message and alarm contact
Voltage low (< 80 % Uo within 1 s) / Action: message and alarm contact
Over voltage (> 110 % Uo) / Action: message and alarm contact
Abnormal cos φ (< 0.5 ind or 0.8 cap) / Action: message and alarm contact
Overtemperature (θ>=θo(θo = 50 °C max)) / Action:message and alarm contact
Over temperature (θ>=θo - 15 °C) / Action: fan switch
Input type Current input CT...X/5 A
Insensitive to CT polarity
Insensitive to phase rotation polarity
Phase to neutral
Phase to phase
Output type Free outputs contacts current: 0.3 A 110 V DC
Free outputs contacts current: 0.6 A 60 V DC
Free outputs contacts current: 1 A 400 V AC 50/60 Hz
Free outputs contacts current: 2 A 24 V DC
Free outputs contacts current: 2 A 250 V AC 50/60 Hz
Free outputs contacts current: 5 A 120 V AC 50/60 Hz
Settings operating mode Automatic
Manual
Type of setting Choice of stepping programs : circular
Choice of stepping programs : linear
Choice of stepping programs : normal
Choice of stepping programs : optimal
Delay between 2 successive switch on the same step : 10...600 s
Step configuration programming
Target cos phi : 0.85 inductive...0.9 capacitive
Measurement accuracy ±5 %
Time delay  10 to 120 s
10 to 600 s on re-connection
Step sequences 1.1.1.1.1.1  1.1.2.2.2.2  1.1.2.3.3.3  1.2.2.2.2.2
1.2.3.3.3.3  1.2.3.4.4.4  1.2.4.4.4.4  1.2.4.8.8.8
Mounting location In cabinet
Panel
Mounting support 35 mm DIN rail conforming to EN 50022
Height  150 mm
Width 150 mm
Depth  70 mm
Product weight 1 kg
Environment
Standards EN 61010-1
IEC 61010-1  IEC 61326
IP Grade IP41 front face; Rear face: IP20
Ambient air temperature for operation 0-60 °C
Ambient air temperature for storage  -20-60 °C
Climatic withstand Ambient air temperature for storage  - 20-60 °C

1. NR12 Power factor controllers control up to 12 capacitor steps
2. Easy to read display
3. Communication option Modbus RS485

The Varlogic controllers permanently measure the reactive power of the installation and control connection and disconnection of capacitor steps to obtain the required power factor. The range is composed of:
NR6 control up to 6 capacitor steps
NR12 control up to 12 capacitor steps
NRC12 control up to 12 capacitor steps and offer more functions and the Modbus communication option They simplify the installation, supervision and maintenance of reactive power compensation equipment
Panel mounting on 35 mm DIN rail (EN 50022)
Insensitive to phase rotation polarity
Standards: IEC 61326 (CEM); IEC 61010-1, EN 61010-1

Benefits
Simplicity, Reliability, Intelligence
Simplicity:
Easy to read display
Intuitive man/machine dialogue

Peace of mind:
Direct display of network and capacitor bank step characteristics
Flexibility:
Automatic programming and commissioning
Communication option Modbus RS485 network (compatible Transparent Ready)
Applications
Swichboards or power factor correction equipment made by panelbuilders or OEMs.

Characteristics
Main
Range of product Varlogic N
Device short name NR12
Language English French German
Portuguese Spanish

Complementary
Number of step output contacts 12
[Us] rated supply voltage 110 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
Measurement current 0...5 A
Measurement voltage 110 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz
Operating mode Manual
Colour code (RAL 7016)
Display type Backlighted screen 65 X 21 mm

Mounting location In cabinet Panel
Mounting support 35 mm DIN rail conforming to EN 50022
Height 150 mm
Width 150 mm
Depth 70 mm
Product weight 1 kg

Environment
Standards EN 61010-1 IEC 61010-1 IEC 61326
IP degree of protection IP41 front face: Rear face: IP20
Ambient air temperature for operation 0...60 ° C
Ambient air temperature for storage -20...60 ° C
Climatic withstand Ambient air temperature for storage: - 20...60 ° C

2000 Pairs Sells per Month
5 pairs MOQ
48-72 hours delivery after received money

About US
YUEQING CITY RUIHUA CABINET WHOLE SET EQUIPMENT is a professional manufacturer of 
low voltage electrical products in South China. 
Our company is committed to design, produce and sale a series of ozone generators air pumps, 
PLC, rotary encoders, HMI, sensors, switches , warning lights, meters and many other electrical 
components. We exports various types of electrical appliances to different countries.

FAQ
Q: Are you a manufacturer or a trade dealer?
A: We are manufacturer with our own factory and trading company.
Q: When did your company start to manufacture the products?
A: We started from the year of 2005.
Q: How can I get some samples?
A: You can send email, buy from our online shop or call us for sample order.
Q:.Can I just buy 1pc sample first or small order?
A:Yes,support sample order and small order, especially for new customers.
Q:.How long to make a sample?
A: We have plenty of stock to support sample order and small order.
Q: Is the sample fee refundable or not?
A:Due to the producing cost is high, we need charge sample fee.
Q:What certification do you have?
A:We have got CE, RoHS certification for our products.
Q:Can I put my own logo?
A:Yes, your logo can be engraved, embossed, transfer-printing or lasered etc.
Q:Is the price including duty?
A: This price does not include customs fee, local taxes, or brokerage fee.
Q:How good is your service and after-sales service?
A: We have excellent customer service & technical support &1-year warranty police to meet all your requirements.
Q: How do your company regard on quality control?
A:Quality is priority. We think highly of quality controlling.

About Payment
 
We provided Trade Assurance service 
We also accept payment by T/T; Western Union, ESCROW, Paypal, Money gram
 
We Provide OEM Services
We can do OEM for your brand (print your logo ). And we can make product according to your design .
The processing method ,the size ,the quality etc ,will all follow your requirement .
 
We do OEM for a lot of the world's leading brands ,we have rich experience in production. We have molds in varieties ,and we have strict  products quality control system.
 
We have a strong R&D team, to develop new products according to the sample you provided.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier